Model NO.: CMS8000VET
Parameters: ECG,NIBP,SpO2,Pr,Temp,Resp
Warranty Period: 18 Months for Main Unit and 6 Months for Accessory
Trademark: CONTEC
Transport Package: Carton
Specification: 43.1*35. *42.5(cm)
Origin: Hebei, China
HS Code: 9018193010
Model NO.: CMS8000VET
Parameters: ECG,NIBP,SpO2,Pr,Temp,Resp
Warranty Period: 18 Months for Main Unit and 6 Months for Accessory
Trademark: CONTEC
Transport Package: Carton
Specification: 43.1*35. *42.5(cm)
Origin: Hebei, China
HS Code: 9018193010
  CONTEC CMS8000VET patient monitor vet veterinary clinic medical equipment
Introduction
CMS8000VET Medical Equipment Animal/Veterinary Monitor Multi-parameter Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements.Veterinary Monitor adopts 100-240V~,50/60Hz for power supply, 12.1'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously.
In addition, Veterinary Multi-parameter Monitor can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system.
Animal Monitor device can monitor such parameters as ECG, RESP, NIBP, SpO2 and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for moving.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECGÂ Â Heart rate (HR)
     ECG waveform
     Arrhythmia and ST-segment analysis
2)RESPÂ Â Respiration rate(RR)
     Respiration waveform
3)SpO2Â Â Oxygen saturation(SpO2)
     Plethysmogram(PLETH) waveform
     Pulse rate(PR)
     Bar graph
4)NIBPÂ Â Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMPÂ Â T1, T2, TD
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc
Features
1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
4)Operation mode: keys and buttons.
5)Display up to 8-channel waveform on one screen.
6)Display 7-lead ECG waveform on one screen, and with ECG step function.
7)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
9)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
10)Drug concentration calculation and titration table functions.
11)Print trend table data with one-key.
12)Connect to Central Monitoring System by 3G, WiFi or wired mode.
13)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Performance
Â
ECG | 1.Lead mode:3-lead or 5-lead 2.Lead select:I, II, III, aVR, aVL, aVF, V 3.Waveform: 5-lead, 2-channel/3-lead, 1-channel 4.Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV 5.Scan speed:12.5mm/s, 25 mm/s, 50 mm/s |
HR: | 1.Measurement and alarm range: 15~350bpm 2.Accuracy:±1% or ±1bpm, whichever is greater 3.Alarm accuracy:± 2 bpm 4.Resolution:1 bpm 5.ST-segment monitoring: 6.Measurement and alarm range: -2.0mV~+2.0mV 7.Accuracy:-0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater 8.Other range: unspecified 9.Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC 10.Pacemaker:yes |
RESPIRATION |
1.Method:R-F(RA-LL) Impedance 2.Respiration rate: Measurement and alarm range: 0~150rpm 3.Resolution:1 rpm 4.Measurement accuracy:  ±2 rpm 5.Alarm accuracy:±3 rpm 6.Apnea alarm:10~40s 7.Scan speed:6.25 mm/s, 12.5 mm/s, 25 mm/s |
NIBP | 1.Method:Oscillometry 2.Mode:Manual/AUTO/STAT 3.Measurement interval in AUTO mode: 4.1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes 5.Measurement period in STAT mode: 5 minutes 6.Measurement and alarm range:10 ~ 270 mmHg 7.Resolution:1 mmHg 8.Cuff pressure accuracy:±3 mmHg 9.Measurement accuracy: 10.Maximal mean error: ±5 mmHg 11.Maximal standard deviation: 8mmHg 12.Over-pressure protection: 13.Other mode:297±3 mmHg   Dog mode:240±3 mmHg   Cat mode:147±3 mmHg |
SpO2 | 1.Measurement and alarm range:0 ~ 100% 2.Resolution:1% 3.Measurement accuracy:70%~100%: ±2%;            0%~69%: unspecified |
PR | 1.Measurement and alarm range:30 ~ 250 bpm 2.Measurement accuracy:±2 bpm or ±2%, whichever is greater |
TEMP | 1.Channel:dual-channel 2.Measurement and alarm range:0 ~ 50ºC 3.Resolution:0.1 ºC 4.Accuracy:±0.1 ºC 5.Power supply:100-240V~,50/60Hz 6.Safety classification:Class I, type CF defibrillation-proof applied part |
Accessories
1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M)
2)General digital SpO2 sensor extension cable (2M)
3)Neonatal capsule single tube repeatable cuff (6-11cm)
4)NIBP extension tube
5)5-lead ECG lead cable (American-Standard)
6)ECG veterinary clip (*5)
7)Transvaginal TEMP probe
8)Power cord
9)User Manual
Physical characteristic
-Dimension: 314mm(L)×145mm(W)×264mm(H)
-Weight: 3.9 Kg
CONTEC MEDICAL SYSTEMS CO., LTD
Product List:
-TELEMEDICINE products
-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products


Introduction
CMS8000VET Medical Equipment Animal/Veterinary Monitor Multi-parameter Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements.Veterinary Monitor adopts 100-240V~,50/60Hz for power supply, 12.1'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously.
In addition, Veterinary Multi-parameter Monitor can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system.
Animal Monitor device can monitor such parameters as ECG, RESP, NIBP, SpO2 and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for moving.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECGÂ Â Heart rate (HR)
     ECG waveform
     Arrhythmia and ST-segment analysis
2)RESPÂ Â Respiration rate(RR)
     Respiration waveform
3)SpO2Â Â Oxygen saturation(SpO2)
     Plethysmogram(PLETH) waveform
     Pulse rate(PR)
     Bar graph
4)NIBPÂ Â Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMPÂ Â T1, T2, TD
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc
Features
1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
4)Operation mode: keys and buttons.
5)Display up to 8-channel waveform on one screen.
6)Display 7-lead ECG waveform on one screen, and with ECG step function.
7)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
9)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
10)Drug concentration calculation and titration table functions.
11)Print trend table data with one-key.
12)Connect to Central Monitoring System by 3G, WiFi or wired mode.
13)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Performance
Â
ECG | 1.Lead mode:3-lead or 5-lead 2.Lead select:I, II, III, aVR, aVL, aVF, V 3.Waveform: 5-lead, 2-channel/3-lead, 1-channel 4.Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV 5.Scan speed:12.5mm/s, 25 mm/s, 50 mm/s |
HR: | 1.Measurement and alarm range: 15~350bpm 2.Accuracy:±1% or ±1bpm, whichever is greater 3.Alarm accuracy:± 2 bpm 4.Resolution:1 bpm 5.ST-segment monitoring: 6.Measurement and alarm range: -2.0mV~+2.0mV 7.Accuracy:-0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater 8.Other range: unspecified 9.Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC 10.Pacemaker:yes |
RESPIRATION |
1.Method:R-F(RA-LL) Impedance 2.Respiration rate: Measurement and alarm range: 0~150rpm 3.Resolution:1 rpm 4.Measurement accuracy:  ±2 rpm 5.Alarm accuracy:±3 rpm 6.Apnea alarm:10~40s 7.Scan speed:6.25 mm/s, 12.5 mm/s, 25 mm/s |
NIBP | 1.Method:Oscillometry 2.Mode:Manual/AUTO/STAT 3.Measurement interval in AUTO mode: 4.1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes 5.Measurement period in STAT mode: 5 minutes 6.Measurement and alarm range:10 ~ 270 mmHg 7.Resolution:1 mmHg 8.Cuff pressure accuracy:±3 mmHg 9.Measurement accuracy: 10.Maximal mean error: ±5 mmHg 11.Maximal standard deviation: 8mmHg 12.Over-pressure protection: 13.Other mode:297±3 mmHg   Dog mode:240±3 mmHg   Cat mode:147±3 mmHg |
SpO2 | 1.Measurement and alarm range:0 ~ 100% 2.Resolution:1% 3.Measurement accuracy:70%~100%: ±2%;            0%~69%: unspecified |
PR | 1.Measurement and alarm range:30 ~ 250 bpm 2.Measurement accuracy:±2 bpm or ±2%, whichever is greater |
TEMP | 1.Channel:dual-channel 2.Measurement and alarm range:0 ~ 50ºC 3.Resolution:0.1 ºC 4.Accuracy:±0.1 ºC 5.Power supply:100-240V~,50/60Hz 6.Safety classification:Class I, type CF defibrillation-proof applied part |
Accessories
1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M)
2)General digital SpO2 sensor extension cable (2M)
3)Neonatal capsule single tube repeatable cuff (6-11cm)
4)NIBP extension tube
5)5-lead ECG lead cable (American-Standard)
6)ECG veterinary clip (*5)
7)Transvaginal TEMP probe
8)Power cord
9)User Manual
Physical characteristic
-Dimension: 314mm(L)×145mm(W)×264mm(H)
-Weight: 3.9 Kg
CONTEC MEDICAL SYSTEMS CO., LTD
Product List:
-TELEMEDICINE products
-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products

Spirulina, Herbal Extract ,Sap & Extract
Goji Berry, Goji Plants Co., Ltd. , http://www.nbredgoji.com