The principle of a clean sampling car
- Clicks:81 Release time:2019/7/18
The clean sampling vehicle (also known as the clean sampling vehicle) is a vertical one-way flow local air purification device that provides a local clean environment. It can be used flexibly in the workshop to make up for the fixed laminar flow hood, air purifier, etc. The cleanliness requirements of certain spaces that the equipment cannot reach.
Clean sampling vehicles are ideal mobile devices for sampling, cargo transportation, etc. in the fields of medicine, health, biological products, food, electronics, etc., and are also necessary equipment as stipulated in Article 22 of GMP. According to the requirements of GMP standards, the sampling vehicles produced by KLCFILTER reach 10,000-class cleanliness (up to 100 levels), and the electrical components used at the same time meet the requirements of GB1497-85 (electric safety standard) and GB-191 (packaging standard). The structure of the clean sampling car consists of stainless steel or spray-coated steel box body. The machine body is composed of pre-filter, blower unit, high-efficiency filter, lighting group, diffuser, combination electric appliance, universal caster, etc. The whole equipment is compact and operates. Convenience.
Clean sampling car working principle:
The working principle of a clean sampling vehicle is in the form of a vertical laminar air flow. The variable speed centrifugal fan presses the air filtered by the pre-filter in the negative pressure tank into the static pressure box, and then performs secondary filtration through the high efficiency filter. The clean airflow from the Rfilter high-efficiency filter exits the working area with a uniform cross-section wind speed to remove dust particles and biological particles, thus forming a dust-free and sterile working environment.
Structural features of a clean sampling car:
1 The upper part of the clean sampling vehicle is the air supply static pressure box, the lower part is the clean area, and the box is made of stainless steel. The air supply body is equipped with a filter made of ultra-fine glass fiber filter material, a multi-wing forward low-noise variable-speed centrifugal fan, and an illumination fluorescent lamp and an ultraviolet germicidal lamp are installed on the wind-side diffuser plate. In order to facilitate the work and observation of the staff, the baffles on both sides of the clean working area are made of transparent glass, and the front and rear windshields are transparent and environmentally friendly materials.
2 The clean sampling vehicle uses a variable speed fan system with adjustable air volume. By adjusting the input voltage of the variable speed fan and changing the working condition of the fan, the average wind speed of the purification working area is always within the ideal range, thereby effectively extending the service life of the main components of the clean sampling vehicle (air high efficiency filter) and reducing The operating cost of a clean sampling car.
3 Ultraviolet germicidal lamps used in clean sampling vehicles can emit strong 2573A short-wave ultraviolet rays. It not only kills the active cells of microorganisms, but also kills highly hot spores (such as Bacillus subtilis spores) and other bacterial spores. In addition, phage and virus can be rapidly destroyed under the action of ultraviolet light. Installation and use conditions of clean sampling vehicles
1 The storage location of the clean sampling vehicle should be kept away from the source, ventilated and dry, and the dust particles with particle size ≥0.5μm per liter of air ≤3500 (equivalent to 100,000 in the US Federal Standard 209B).
2 The clean sampling vehicle has adjusted the wind speed to a good state (that is, the average wind speed in the purification working area is 0.32m/s to 0.48m/s)
3 After the clean sampling vehicle is installed, the average wind speed of the purification working area can be measured with a differential meter. The wind speed is controlled from 0.32m/s to 0.48m/s (adjusted voltage).
Clean sampling vehicle operating procedures and precautions
1 When using a clean sampling vehicle, the ultraviolet germicidal lamp should be turned on 50 minutes in advance to process the microorganisms accumulated on the surface of the clean sampling vehicle in the clean working area; after 30 minutes, the germicidal lamp is turned off and the blower is activated.
2 Newly installed or long-term unused clean sampling vehicles must be carefully cleaned before use, using clean vacuum cleaners or tools that do not produce fibers, and then using pharmaceutical sterilization or UV. Sterilization is carried out by sterilization.
3 It is strictly forbidden to store unnecessary items in the purification work area to keep the clean air flow pattern undisturbed.
4 In the purification work area, try to avoid the action of obviously disturbing the airflow pattern.
5 Regularly (usually once a month) use an anemometer to measure the average wind speed in the work area. If it is found that it does not meet the technical specifications, the regulator handle should be adjusted to change the input voltage of the fan to make the clean sampling vehicle in good working condition.
6 Clean sampling vehicle use temperature should be no more than 50 degrees Celsius clean sample car repair and maintenance
1 According to the cleanliness of the environment, the filter material in the coarse filter is periodically removed and cleaned, and the interval is usually 2 to 3 months. Under normal circumstances, when the non-woven filter material contains more dust particles and the surface is black, it can be removed for cleaning or replaced.
2 Periodically (usually one week) to sterilize the environment.
3 Use the dust particle counter to measure the cleanliness of the work area every three months, and use the plate method to determine the average number of colonies of the clean sample car. When the technical parameters are not met, the cause must be found and repaired in time.
4 When increasing the input voltage of the fan can not make the average wind speed of the purification working area reach 0.32m/s~0.48m/s, it indicates that the dust holding capacity of the air high efficiency filter has become saturated and has to be replaced.
5 Replace the high-efficiency filter and open it after opening the top cover of the clean sampling car. When placing the high-efficiency air filter, point the arrow mark to the direction of airflow (ie downward)
6 After replacing the high-efficiency filter, the dust particle counter should be used to check whether the surrounding frame seal is good. If necessary, the silica gel can be used to block the leak. Then adjust the fan input voltage to keep the average wind speed in the purification working area between 0.32m/s and 0.48m/s. Within the scope.
7 Always wipe the surface of the UV germicidal lamp with gauze and alcohol/acetone lamp solution to keep the surface clean, otherwise it will affect the sterilization ability.
8 Electrical faults can be repaired with reference to electrical schematics and electrical wiring diagrams
9 Perform a maintenance check once a month and fill in the instrument maintenance record
10 After each use, clean the instrument immediately, and hang the corresponding mark, fill in the instrument usage record in time.
Clean sampling car cleaning
1 After the material is taken, use a brush to clean the debris and dust from the work area.
2 Wipe the surface stains and dirt on the work surface with a soft cloth. Visually, there is no detergent residue. Wipe dry with a cleaning cloth.
3 Always wipe the surface of the UV germicidal lamp with gauze and alcohol to keep the surface clean, otherwise it will affect the sterilization ability.
4 Effect evaluation: The inner and outer surfaces of the equipment should be bright and tidy, without smudging.
Pain Relief Patch for Breast
[Name] Medical Cold Patch
[Package Dimension] 10 round pieces
The pain relief patch is composed of three layers, namely, backing lining, middle gel and protective film. It is free from pharmacological, immunological or metabolic ingredients.
[Scope of Application] For cold physiotherapy, closed soft tissue only.
[Indications]
The patches give fast acting pain relief for breast hyperplasia, breast fibroids, mastitis, breast agglomera tion, swollen pain.
[How To Use a Patch]
Please follow the Schematic Diagram. One piece, one time.
The curing effect of each piece can last for 6-8 hours.
[Attention]
Do not apply the patch on the problematic skin, such as wounds, eczema, dermatitis,or in the eyes. People allergic to herbs and the pregnant are advised not to use the medication. If swelling or irritation occurs, please stop using and if any of these effects persist or worsen.notify your doctor or pharmacist promptly. Children using the patch must be supervised by adults.
[Storage Conditions]
Store below 30c in a dry place away from heat and direct sunlight.
Pain Relief Patch For Breast,Pain Relief Plaster For Breast,Relief For Breast Pain,Pad Relief Patch For Breast
Shandong XiJieYiTong International Trade Co.,Ltd. , https://www.xjytmedical.com